ESD Clogs for men and women | Electric Static Dissipative footwear

B.A.S.S. (Belgium's-A-StaticScience) * ESD prevention clearly distinguish the difference between an ESD work shoe and an ESD Safety Shoe.  ESD shoes, to whom belong ESD Clogs, have an electrostatically dissipative conductive shoe sole, popularly known as antistatic shoes (which is not the same, incorrectly).  Safety Shoes are classed as ESD safe shoes when the resistance value of the system person-shoe-floor is below 3,5 x 10^7 resp. 35 MOhm according to EN 61340-5-1. 

INTERNATIONAL STANDARD-ESD IEC 61340-5-1 Edition 1.0 2007-08 INTERNATIONAL STANDARD-ESD IEC 61340-5-1 Edition 1.0 2007-08

IEC 61340-4-3, Electrostatics Part 4-3: Standard test methods for specific applications : Footwear

IEC 61340-4-5, Electrostatics Part 4-5: Standard test methods for specific applications : Methods for characterizing the electrostatic protection of footwear and flooring in combination with a person.

5.3.2 Personnel grounding

For standing operations, personnel can be grounded via a wrist strap system or by a flooringfootwear system. When a flooring-footwear system is used, either of the two following conditions shall be met:

  • the total resistance of the system (from the person, through the footwear and flooring to equipment ground) shall be less than 3,5 × 107 ?;
  • the maximum body voltage generation shall be less than 100 V and the total resistance of the system shall be less than 1 x109 ?.

ESD footweare according 61340-5-1 © IEC-2007 Personnel grounding requirements

A.2 Measurement procedure for ESD-footwear testing 

The operator shall stand with one foot on the conductive footwear electrode. The hand contact plate shall be pressed to verify that the person/footwear system resistance is within acceptable parameters (see Figure A.2). The test shall be repeated for the other foot. The test apparatus can be an integrated, commercially available tester or other instrumentation that is capable of measuring resistance from 5,0x104 Ω to at least 1,0x108 Ω. The tester open-circuit voltage is typically between 9 V d.c.and 100 V d.c.

Measurement procedure for ESD-footwear testing

Categories ESD Safe Working Shoes:

Warning: 
ESD shoes are not suitable for electricians respectively when working on sources with electric voltage.

1.
218-95-W24-0035
EAN : 6438157104014

ESD clogs for ladies -File White- size 35

  • Size: 35
  • Men's or Women: Women
  • Weight: 0.62 Kg
  • Safety type:: WS
2.
218-95-M30-0039
EAN : 6438157104052

ESD clogs for gentlemen -File White- size 39

  • Size: 39
  • Men's or Women: Men
  • Weight: 0.78 Kg
  • Safety type:: WS
3.
218-95-M04-0039
EAN : 6438157086501

ESD clogs for gentlemen -File Black- size 39

  • Size: 39
  • Men's or Women: Men
  • Weight: 0.78 Kg
  • Safety type:: WS
4.
218-95-W05-0035
EAN : 6438157086464

ESD clogs for ladies -File Black- size 35

  • Size: 35
  • Men's or Women: Women
  • Weight: 0.62 Kg
  • Safety type:: WS
5.
218-91-W14-0035
EAN : 6438157088550

ESD Clogs -Monica Black- for ladies size 35

  • Size: 35
  • Men's or Women: Women
  • Weight: 0.56 Kg
  • Safety type:: WS